Improve outcomes and workflow while transforming care delivery across clinical pathways. The epoc® Blood Analysis System gives you lab-quality results here and now.
The epoc system is a handheld, wireless solution to enable comprehensive blood analysis testing at the patient’s side on a single room temperature test card, with results in less than a minute.
- Streamline patient-testing workflow.
- Accelerate clinical decision making.
- Simplify inventory management.
- Deliver real-time results and reporting.
Features & Benefits

Streamline patient-testing workflow.
By moving testing to the patient’s side, caregivers, patients, and hospital administration all benefit from a less-complex testing process that improves turnaround times, patient care, and operational efficiencies.

Accelerate clinical decision making.
Empower clinicians to make faster decisions with lab-quality results at the patient’s side, enhancing clinical decision making and improving patient outcomes.

Simplify inventory management.
By incorporating a full menu on a single, room temperature-stable test card bar-coded for quality assurance, the epoc system delivers a more efficient and easy-to-manage patient-side testing program.
Assays
Measured Parameters |
|
|
Parameter |
Unit of Measure |
Measurement Range |
pH |
pH units |
6.5–8.0 |
pCO2 |
mmHg |
5-250 |
|
kPa |
0.7-33.3 |
pO2 |
mmHg |
5–750 |
|
kPa |
0.7–100 |
TCO2 |
mmol/L |
5-50 |
|
mEq/L |
|
Na+ |
mmol/L |
85–180 |
|
mEq/L |
|
K+ |
mmol/L |
1.5–12.0 |
|
mEq/L |
|
Ca++ |
mmol/L |
0.25–4.00 |
|
mg/dL |
1.0–16.0 |
|
mEq/L |
0.5–8.0 |
Cl- |
mmol/L |
65–140 |
|
mEq/L |
|
Hct |
% PCV |
10–75 |
|
L/L |
0.10–0.75 |
Glu |
mmol/L |
1.1–38.5 |
|
mg/dL |
20-700 |
|
g/L |
0.20-7.00 |
Lac |
mmol/L |
0.30–20.00 |
|
mg/dL |
2.7–180.2 |
|
g/L |
0.03–1.80 |
Crea |
mg/dL |
0.30–15.00 |
|
μmol/L |
27–1326 |
BUN |
mg/dL |
3-120 |
Urea |
mmol/L |
1.1-42.8 |
|
mg/dL |
7-257 |
|
g/L |
0.07-2.57 |
Calculated Parameters |
|
|
Parameter |
Unit of Measure |
Measurement Range |
cHgb |
mmol/L |
2.0-15.5 |
|
g/dL |
3.3-25 |
|
g/L |
33-250 |
cHCO3– |
mmol/L |
1-85 |
|
mEq/L |
|
cTCO2 |
mmol/L |
1-85 |
|
mEq/L |
|
BE(ecf) |
mmol/L |
30 – +30 |
|
mEq/L |
|
BE(b) |
mmol/L |
-30 – +30 |
|
mEq/L |
|
cSO2 |
% |
0-100 |
GFRmdr*† |
mL/min/1.73m2 |
2–60 or >60 |
GFRmdr-a*† |
mL/min/1.73m2 |
2–60 or >60 |
GFRckd‡ |
mL/min/1.73m2 |
1-225 |
GFRckd-a‡ |
mL/min/1.73m2 |
1-225 |
GFRswz§ |
mL/min/1.73m2 |
1-275 |
AGap |
mmol/L |
-14 – +95 |
|
mEq/L |
|
AGapK |
mmol/L |
-10 – +99 |
|
mEq/L |
|
BUN/Crea |
mg/mg |
0.2-400.0 |
Urea/Crea |
mmol/mmol |
0.8-1615.4 |
|
mg/mg |
0.4-856.8 |
A |
mmHg |
5-800 |
|
kPa |
0.67-106.64 |
A-a |
mmHg |
1-800 |
|
kPa |
0.13-106.64 |
a/A |
% |
0-100 |
|
fraction |
0-1 |
Technical Details
Sample Size |
|
Sample volume |
At least 92 μL |
|
|
Analysis |
|
Time to result |
Less than 1 minute |
|
|
Quality Control |
|
|
Eurotrol GAS-ISE Metabolite control; |
|
|
Test Card |
|
Calibration |
Automatically performed prior to every test |
Storage |
15–30°C |
Shelf life |
Up to 5 months |
|
|
Integrated Barcode Scanner |
|
|
Patient ID and Operator ID; |
|
|
Operating System |
|
|
MICROSOFT Windows |
|
|
Communications |
|
|
Real Time Wireless, LIS/HIS via data management system, |